Quick
Search: 
 
advanced search
 GSW Home    GeoRef Home    My GSW Alerts    Contact GSW    About GSW    Journals List    Help 
The Leading Edge Email Content Delivery
JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS

The Leading Edge; June 2003; v. 22; no. 6; p. 555-556; DOI: 10.1190/1.1587676
© 2003 Society of Exploration Geophysicists
This Article
Right arrow Figures Only
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Taylor, R.
Right arrow Articles by Doolittle, J.
Right arrow Search for Related Content
GeoRef
Right arrow GeoRef Citation

Ground conductivity survey of a septic system during and after failure

Rick Taylor

Dualem, Milton, Ontario, Canada

Brad Lee

Purdue University, West Lafayette, Indiana, U.S.

Jim Doolittle

USDA-NRCS, Newtown Square, Pennsylvania, U.S.

Corresponding author: mail@dualem.com

Editor's note: The use of trade names is for descriptive purposes only, and does not imply particular endorsement by the authors or SEG.

The first 20% of the full text of this article appears below.

Many people (e.g., 25% of the U.S. population) use septic systems for wastewater disposal. In the United States, county health departments typically are responsible for overseeing the installation and operation of these systems. Because most systems rely on the soil to absorb the wastewater, special attention is required where the hydraulic permeability of soils may allow contamination to reach either the surface or a nearby aquifer. Electromagnetic induction (EMI) provides an efficient means for observing septic system performance and for guiding costlier onsite investigations.

In 2001, the Ft. Wayne–Allen County Health Department identified several failing septic systems in the suburbs of Ft. Wayne, Indiana, U.S., through field observation and water-quality monitoring of nearby streams. One such system had been installed in a fine-textured (35–50% clay) soil of low permeability, and serviced a residence on a two-acre lot.

The system was mapped in December 2001 and again in July 2002 with the DUALEM-2 and several other EMI instruments. The DUALEM-2 is designed to measure ground conductivity at low-induction-number (LIN). The instrument contains coils that operate in both the horizontal coplanar (HCP) and perpendicular (PRP) geometries. Transmitter-receiver separation is about 2 m. At LIN, the PRP geometry is sensitive to conductivity fluctuations to a depth of about 1.2 m beneath the instrument, and the HCP geometry is sensitive to a depth of about 3 m.

To evaluate the location of the septic system absorption field and contaminant distribution, the instrument was carried at low ground-clearance aligned with north-south traverses spaced at 2-m intervals (Figure 1). Although the surveys progressed along serpentine paths, the transmitter-receiver orientation of the instrument was kept consistent. Continuous measurements were recorded at walking speed (about 1.2 m/s). A 1-Hz sample rate was used in December; in July a 2-Hz rate was used.


Figure Removed (Available Only in the Full Text)
View larger version (112K):
[in this window]
[in a new window]
 
Figure 1. Recording measurements while progressing . . . [Full Text of this Article]

 






JOURNAL HOME HELP CONTACT PUBLISHER SUBSCRIBE ARCHIVE SEARCH TABLE OF CONTENTS
Copyright © 2009 by Society of Exploration Geophysicists